Stranded Copper Conductor
PVC / Heat-Resistant PVC Insulation and
Jacket
Application:
Indoor Cords for Use in Electrical
Appliances of A.C. 300V or Less
Temperature Rating:
60℃, 75℃ Heat Resistant
Standard: JIS C 3306
Rating: 300V
No.of Conductor
Conductor
Insulation
Section Area (mm2)
Contruction (No./mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
2
0.50
20 / 0.18
0.80
2.5 x 5.0
2
0.75
30 / 0.18
0.80
2.7 x 5.4
2
1.25
50 / 0.18
0.80
3.1 x 6.2
2
2.00
41 / 0.25
0.80
3.4 x 6.8
Marking: E JET IMPORT NAME VFF Size mm260℃ YEAR- F-D.Q.CHAU'S E. E JET IMPORT NAME HVFF Size mm2 75℃ YEAR-F - D.Q.CHAU'SE.
VCTF / HVCTF
No.of Conductor
Conductor
Insulation
Jacket
Section Area (mm2)
Contruction (No./mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
2
0.75
30 / 0.18
0.60
2.40
1.00
6.90
2
1.25
50 / 0.18
0.60
2.75
1.00
7.60
2
2.00
41 / 0.25
0.60
3.15
1.00
8.40
3
0.75
30 / 0.18
0.60
2.40
1.00
7.25
3
1.25
50 / 0.18
0.60
2.75
1.00
8.00
3
2.00
41 / 0.25
0.60
3.15
1.00
8.85
4
0.75
30 / 0.18
0.60
2.40
1.00
7.95
4
1.25
50 / 0.18
0.60
2.75
1.00
8.80
4
2.00
41 / 0.25
0.60
3.15
1.00
9.80
Marking: E JET IMPORT NAME VCTF Size mm260℃ YEAR- F-D.Q.CHAU'S E. E JET IMPORT NAME HVCTF Size mm2 75℃ YEAR-F - D.Q.CHAU'SE
VSF / HVSF
Conductor
Insulation
Section Area (mm2)
Contruction (No./mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
0.50
20 / 0.18
0.80
2.50
0.75
30 / 0.18
0.80
2.70
1.25
50 / 0.18
0.80
3.10
2.00
41 / 0.25
0.80
3.40
Marking: E JET IMPORT NAME VSF Size mm260℃ YEAR- F-D.Q.CHAU'S E. E JET IMPORT NAME HVSF Size mm2 75℃ YEAR-F - D.Q.CHAU'SE
VCTFK / HVCTFK
No.of Conductor
Conductor
Insulation
Jacket
Section Area (mm2)
Contruction (No./mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
2
0.75
30 / 0.18
0.60
2.40
0.60
4.5 x 6.6
2
1.25
50 / 0.18
0.60
2.75
0.60
4.9 x 7.4
2
2.00
41 / 0.25
0.60
3.15
0.60
5.3 x 8.0
Marking: E JET IMPORT NAME VCTFK Size mm260℃ YEAR- F-D.Q.CHAU'S E. E JET IMPORT NAME HVCTFK Size mm2 75℃ YEAR-F - D.Q.CHAU'SE
TINSEL CORD
No.of Conductor
Conductor
Insulation
Section Area (mm2)
Contruction (No./mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
2
0.10
18 (Tinsel)
0.80
2.8 x 5.5
Marking:
12-9025 D.Q.CHAU'S E.
60227 IEC 52 (300 / 300V)
No.of Conductor
Conductor
Insulation
Jacket
Section Area (mm2)
Contruction (No./mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
2
0.50
29 / 0.15
0.5
1.95
0.6
5.20
2
0.50
29 / 0.15
0.5
1.95
0.6
3.25 x 5.2
2
0.75
43 / 0.15
0.5
2.15
0.6
5.60
2
0.75
43 / 0.15
0.5
2.15
0.6
3.6 x 5.75
3
0.50
29 / 0.15
0.5
1.95
0.6
5.50
3
0.75
43 / 0.15
0.5
2.15
0.6
5.90
Marking: E JET IMPORT NAME 60227 IEC 52 Size mm2 YEAR D.Q.CHAU'S E.
60227 IEC 53 (300 / 500V)
No.of Conductor
Conductor
Insulation
Jacket
Section Area (mm2)
Contruction (No./mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
2
0.75
43 / 0.15
0.6
2.35
0.8
6.30
2
0.75
43 / 0.15
0.6
2.35
0.8
4.1 x 6.5
2
1.00
32 / 0.15
0.6
2.55
0.8
6.80
2
1.00
32 / 0.15
0.6
2.55
0.8
4.35 x 6.9
2
1.50
30 / 0.253
0.7
3.00
0.8
7.80
2
2.50
50 / 0.253
0.8
3.65
1.0
9.30
3
0.75
43 / 0.15
0.6
2.35
0.8
7.00
3
1.00
32 / 0.2
0.6
2.55
0.8
7.20
3
1.50
30 / 0.253
0.7
3.00
0.9
8.30
3
2.50
50 / 0.253
0.8
3.65
1.1
10.10
Marking: E JET IMPORT NAME 60227 IEC 53 Size mm2 YEAR D.Q.CHAU'S E.
VCT
Standard: JISC 3312: 1987
Rating: 600V
No.of Conductor
Conductor
Insulation
Jacket
Section Area (mm2)
Contruction (No./mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
Nom.Thick. (mm)
Nom.Diam. (mm)
2
0.75
30 / 0.18
0.8
2.75
1.7
8.80
2
1.25
50 / 0.18
0.8
3.10
1.7
9.60
2
2.00
41 / 0.25
0.8
3.45
1.8
10.5
3
0.75
30 / 0.18
0.8
2.75
1.7
9.20
3
1.25
50 / 0.18
0.8
3.10
1.7
10.5
3
2.00
41 / 0.25
0.8
3.45
1.8
11.0
4
0.75
30 / 0.18
0.8
2.75
1.7
9.90
4
1.25
50 / 0.18
0.8
3.10
1.8
11.2
4
2.00
41 / 0.25
0.8
3.45
1.8
12.0
Marking:
12-9835 D.Q. CHAU'S E. VCT Size mm2YEAR-F.